● The actuators are used primarily for the load-dependent control of the
flow of gas, oil volume, and combustion air volume in connection with
the electronic ratio control LMV27 / LMV37.
● Areas of application are oil and gas burners of medium to larger capacity.
● Standards & Certifications:
● The SQM33 actuators are of robust design and have a gear train with only little backlash.
● Control and position feedback take place via a common cable.
● The actuators are driven by stepper motors and can be positioned with a resolution of 0.1°.
● The running times of the controlling elements are varied by the basic unit depending on the burner’s control phase